 CFMEGA2 is an industrial controller based on the ATmega2560 microcontroller. CFMEGA2 is an industrial controller based on the ATmega2560 microcontroller.
Line 15: Line 9:
 Power supply: 12–24 VDC with approximately 0.5 W power consumption. Power supply: 12–24 VDC with approximately 0.5 W power consumption.
 Operating temperature range: 0 °C to 60 °C. Operating temperature range: 0 °C to 60 °C.
-Status: Available. 
  
 CFMEGA1 is an industrial controller planned for release. CFMEGA1 is an industrial controller planned for release.
Line 26: Line 19:
 Power supply: 12–24 VDC. Power supply: 12–24 VDC.
 Operating temperature range: 0 °C to 60 °C. Operating temperature range: 0 °C to 60 °C.
-StatusComing soon.+ 
 +CFDI-16B is a digital input module with 16 channels designed for DC 24 V signals. 
 +Each input channel is opto-coupler isolated. 
 +Address range0 to 7. 
 +Maximum modules per system: 8 (system limit is 16 total I/O modules). 
 +Power consumption: approximately 0.25 W. 
 +Category: Digital Input. 
 + 
 +CFDO-16N is a digital output module with 16 NPN transistor outputs. 
 +Output voltage range: DC 5 V to 24 V with a maximum current of 120 mA per channel. 
 +Address range: 0 to 7 (shares address space with CFDO-8R). 
 +Maximum modules per system: 8. 
 +Power consumption: approximately 0.55 W. 
 +Category: Digital Output. 
 + 
 +CFDO-8R is a relay output module with 8 channels using dry-contact relays. 
 +Rated switching voltage: 110 VAC to 240 VAC. 
 +Address range: shared with CFDO-16N (no separate address block). 
 +Maximum modules per system: 8. 
 +Power consumption: approximately 0.25 W. 
 +Category: Digital Output. 
 + 
 +CFADC-A4L is an analog input module with 4 channels. 
 +Input types: 0–20 mA or 0–10 VDC. 
 +Resolution: 14.7-bit. 
 +Address range: 0 to 3. 
 +Maximum modules per system: 4. 
 +Power consumption: approximately 0.075 W. 
 +Category: Analog Input. 
 + 
 +CFDAC-2V is an analog output module with 2 channels. 
 +Output range: 0–10 VDC. 
 +Resolution: 12-bit. 
 +Address range: 0 to 7. 
 +Maximum modules per system: 8. 
 +Power consumption: approximately 0.05 W. 
 +Category: Analog Output. 
 + 
 +CFTC-1L is a thermocouple input module with 1 channel. 
 +Measurement range: −50 °C to 500 °C. 
 +Address range: 0 to 7. 
 +Maximum modules per system: 8. 
 +Power consumption: approximately 0.05 W. 
 +Category: Analog Input.
 ++++ ++++
  
 +====== Modular FADUINO ======
 +
 +  * [[product_warning:index|Warning]]
 The Modular FADUINO is an Arduino(("Arduino" name and logo are trademarks registered by Arduino S.r.l. in Italy.)) compatible industrial controller.  The Modular FADUINO is an Arduino(("Arduino" name and logo are trademarks registered by Arduino S.r.l. in Italy.)) compatible industrial controller. 
  
Line 70: Line 109:
  
  
-^                                                                                                        ^  CFDI-16B                  CFDO-16N                                                CFDO-8R                                ^  CFADC-A4L                                         CFDAC-2V                              CFTC-1L                                          ^+^                                                                                                        ^  CFDI-16B                  CFDO-16N                                                CFDO-8R                                ^  CFADC-4L                                         CFDAC-2V                              CFTC-1L                                          ^
 ^ Detailed Information                                                                                    [[.:cfdi16b|[Click]]]    |  [[.:cfdo16n|[Click]]]                                  |  [[.:cfdo8r|[Click]]]                    [[.:cfadca4l|[Click]]]                            [[.:cfdac2v|[Click]]]                |  [[.:cftc1l|[Click]]]                             | ^ Detailed Information                                                                                    [[.:cfdi16b|[Click]]]    |  [[.:cfdo16n|[Click]]]                                  |  [[.:cfdo8r|[Click]]]                    [[.:cfadca4l|[Click]]]                            [[.:cfdac2v|[Click]]]                |  [[.:cftc1l|[Click]]]                             |
 ^ Category                                                                                                Digital Input            |  Digital Output                                          Digital Output                          Analog Input                                      Analog Output                        |  Analog Input                                     | ^ Category                                                                                                Digital Input            |  Digital Output                                          Digital Output                          Analog Input                                      Analog Output                        |  Analog Input                                     |
Line 78: Line 117:
 ^ How many can be used \\  on one system((The maximum number of I/O modules used in one system is 16.))  |  8                        |  8                                                                                               ||  4                                                |  8                                    |  8                                                | ^ How many can be used \\  on one system((The maximum number of I/O modules used in one system is 16.))  |  8                        |  8                                                                                               ||  4                                                |  8                                    |  8                                                |
 ^ Current consumption                                                                                    |  0.25W                    |  0.55W                                                  |  0.25W                                  |  0.075W                                            0.05W                                |  0.05W                                            | ^ Current consumption                                                                                    |  0.25W                    |  0.55W                                                  |  0.25W                                  |  0.075W                                            0.05W                                |  0.05W                                            |
 +
 +  * [[.:Dimension]]
  
 ====== Connect with ComfileHMI ====== ====== Connect with ComfileHMI ======
Line 83: Line 124:
   * [[.:FADUINOComfileHMI|Connecting with a ComfileHMI]]   * [[.:FADUINOComfileHMI|Connecting with a ComfileHMI]]
   * [[.:ComfileHMIEXAMPLE|ComfileHMI Example]]   * [[.:ComfileHMIEXAMPLE|ComfileHMI Example]]
-====== Industrial Application (IEC61131-3 library) ====== 
- 
-  - [[.:ManagedCodeBase|Description]] 
-  - [[.:ManagedCodeBaseLib|Managed Code base Libaray]] 
-  - [[.:ManagedCodeBaseLib2|IEC 61131-3 library]] 
-  - [[.:ManagedLibExample1|Examples]] 
- 
  
 ====== Simple User Interface ====== ====== Simple User Interface ======
Line 97: Line 131:
  
   * Q : Does it operate on IEC 61131-3 software such as OPENPLC?   * Q : Does it operate on IEC 61131-3 software such as OPENPLC?
-    * No. This product has not been tested on OPENPLC. However, it supports related libraries so that you can feel as if you are using the ST language of IEC61131-3.+    * A : No. This product has not been tested on OPENPLC. However, it supports related libraries so that you can feel as if you are using the ST language of IEC61131-3.
  
   * Q : Can I connect to HMI?   * Q : Can I connect to HMI?
-    * It can be connected to our company's product, ComfileHMI, and provides libraries related to it. It cannot be connected to HMI from other companies.+    * A : It can be connected to our company's product, ComfileHMI, and provides libraries related to it. It cannot be connected to HMI from other companies.
  
   * Q : There is existing equipment with Allen-Bradley PLC. PLC is too expensive, so I want to change to Modular FADUINO. Is it possible?   * Q : There is existing equipment with Allen-Bradley PLC. PLC is too expensive, so I want to change to Modular FADUINO. Is it possible?
-    * PLCs are usually programmed using Ladder Logic. Ladder Logic cannot be converted to C language. Therefore, the existing system cannot be replaced directly with this product.+    * A : PLCs are usually programmed using Ladder Logic. Ladder Logic cannot be converted to C language. Therefore, the existing system cannot be replaced directly with this product.
  
 [[:index|COMFILE Technology's Documentation Library]] [[:index|COMFILE Technology's Documentation Library]]
modularfaduino/index.1771219593.txt.gz · Last modified: by admin