 Think of the isolated side as an island. There should be no direct electrical connection between the two sides. Think of the isolated side as an island. There should be no direct electrical connection between the two sides.
  
-{{ :noise_book:isolation.png?nolink |}}+{{ :noise_book:opto_circuit.png?nolink |}}
  
 For this reason, isolated power supplies are just as important as optocouplers. An isolated DC/DC converter is commonly used to provide power to the isolated side while keeping the grounds separated. For this reason, isolated power supplies are just as important as optocouplers. An isolated DC/DC converter is commonly used to provide power to the isolated side while keeping the grounds separated.
  
 Be careful when selecting DC/DC converters. Some low-cost products may provide voltage conversion but do not provide true isolation. Always check the specifications to confirm that the input and output grounds are isolated. Be careful when selecting DC/DC converters. Some low-cost products may provide voltage conversion but do not provide true isolation. Always check the specifications to confirm that the input and output grounds are isolated.
 +
 +{{ :noise_book:dcdc.png?nolink |}}
  
 Is isolation the best solution for noise problems? Is isolation the best solution for noise problems?